Sample data. These listings are fictional examples used to demonstrate the site. No MLS or board data is displayed.

Shaun Lovell, Real Estate SalespersonRight At Home Realty, Brokerage289-813-3318

Toronto address · Ward 5, York South-Weston

82 Buttonwood Ave

West Park Hospital

The City of Toronto has 74 building permits since 2017 (44 still open) and 1 Committee of Adjustment file on record for this address.

Building permits

Every permit the City lists for this address since 2017, and any still open from before, newest first.

  • Addition or alteration · Multiple projects

    REV 05: Replacement of Generator in existing Central Utility Plant Generator Rm. New Generator requires updated mechanical design, structural alterations to the exterior of the building, and new architectural louversRevision: Washroom and locker room

    Applied Aug 12, 2026 · issued Sep 3, 2026 · Permit 24 226092 BLD (revision 05)

    Revision issued
  • Heating and ventilation

    REV 04: Replacement of Generator in existing Central Utility Plant Generator Rm. New Generator requires updated mechanical design, structural alterations to the exterior of the building, and new architectural louversRevision: Washroom and locker room

    Applied Aug 12, 2026 · issued Aug 21, 2026 · Permit 24 226092 HVA (revision 04)

    Revision issued
  • Plumbing

    Revision: Washroom and locker room

    Applied Jun 17, 2026 · issued Jun 24, 2026 · Permit 24 226092 PLB (revision 03)

    Revision issued
  • Heating and ventilation

    Revision: Washroom and locker room

    Applied Jun 11, 2026 · issued Jun 15, 2026 · Permit 24 226092 HVA (revision 03)

    Revision issued
  • Addition or alteration · Multiple projects

    Revision: Washroom and locker room

    Applied Jun 11, 2026 · issued Jun 29, 2026 · Permit 24 226092 BLD (revision 04)

    Revision issued
  • Conditional permit · Inside and outside drains

    Conditional Permit - Drain - Proposal to construct a maintenance shed/garage next to the existing 3 storey long term care building.

    Applied Mar 18, 2026 · issued Apr 14, 2026 · Permit 24 245143 STS

    Inspections under way
  • Addition or alteration · Multiple projects

    Revision: Removal of all plant material and roofing from the terrace, installation of new roof membrane and reinstatement of terrace

    Applied Mar 3, 2026 · issued Mar 31, 2026 · Permit 24 226092 BLD (revision 03)

    Revision issued
  • Addition or alteration · Multiple projects

    Revision: use the existing fire pump for supplying the east tower sprinkler systems for phase 01.

    Applied Oct 31, 2025 · issued Nov 24, 2025 · Permit 24 226092 BLD (revision 02)

    Revision issued
  • Conditional permit · Partial permit - structural framing

    Conditional Permit - Part Permit - Proposal to construct a maintenance shed/garage next to the existing 3 storey long term care building.

    Applied Oct 31, 2025 · issued Jan 8, 2026 · Permit 24 245143 STR

    Inspections under way
  • Partial permit · Partial permit - structural framing

    Part Permit - Reactivation Care Centre exterior wall alterations to accommodate proposed adjacent hospital building revision (included but not limited to retaining wall running along the exterior perimeter of RCC, waterproofing, etc). And a new green roof (VN).

    Applied Oct 31, 2025 · issued Nov 21, 2025 · completed Nov 21, 2025 · Permit 25 109866 STR

    Closed
  • Designated structure · Sign building permit related

    1 ground sign with full colour LED display**WEST PARK HEALTHCARE CENTRE**

    Applied Oct 30, 2025 · issued Nov 10, 2025 · completed May 28, 2026 · Permit 25 247034 DST

    Closed
  • Plumbing

    REV Plumbing - Temporary mechanical equipmentProposal to construct interior alterations in an existing care facility - UHN Reactivation Care Centre

    Applied Oct 21, 2025 · issued Oct 27, 2025 · Permit 24 226092 PLB (revision 02)

    Revision issued
Show 62 more permits
  • Heating and ventilation

    REV HVAC - Proposal for temporary mechanical equipmentProposal to construct interior alterations in an existing care facility - UHN Reactivation Care Centre

    Applied Oct 21, 2025 · issued Oct 27, 2025 · Permit 24 226092 HVA (revision 02)

    Revision issued
  • Designated structure · Other

    Proposal to relocate the existing sign, install new concrete footings and, reconnect electrical power on the n/w corner of Emmett Ave and Eglinton Ave W. (West Park Care Centre)

    Applied Oct 9, 2025 · issued Jan 15, 2026 · Permit 25 237984 DST

    Permit issued
  • Designated structure · Sign building permit related

    29 signs as per 2025 120039 ZMP 00 ZR

    Applied Jul 16, 2025 · issued Oct 24, 2025 · Permit 25 194969 DST

    Inspections under way
  • Fire and security upgrade · Electromagnetic locks

    Proposed fire/security upgrade, office, electromagnetic locks - 12 maglockseast tower - to install 3 single maglocks on level 2 and level 3west tower - to install 3 single maglocks on level 2 and level 3

    Applied Jul 11, 2025 · issued Jul 16, 2025 · completed Sep 11, 2026 · Permit 25 192319 FSU

    Closed
  • Plumbing

    Revision: mechanical, electrical, drainage, kitchen equipment and finishes upgrades to the existing kitchen and dishroom.

    Applied Jul 11, 2025 · issued Jul 15, 2025 · Permit 24 226092 PLB (revision 01)

    Revision issued
  • Heating and ventilation

    Revision: mechanical, electrical, drainage, kitchen equipment and finishes upgrades to the existing kitchen and dishroom.

    Applied Jul 11, 2025 · issued Jul 15, 2025 · Permit 24 226092 HVA (revision 01)

    Revision issued
  • Addition or alteration · Multiple projects

    Revision: mechanical, electrical, drainage, kitchen equipment and finishes upgrades to the existing kitchen and dishroom.

    Applied Jul 11, 2025 · issued Aug 6, 2025 · Permit 24 226092 BLD (revision 01)

    Revision issued
  • Drains and site services

    Drain - Reactivation Care Centre exterior wall alterations to accommodate proposed adjacent hospital building revision (included but not limited to retaining wall running along the exterior perimeter of RCC, waterproofing, etc)

    Applied Jan 29, 2025 · issued Nov 21, 2025 · Permit 25 109866 DRN

    Inspections under way
  • Drains and site services · Site service

    Drain -Site Service- Reactivation Care Centre exterior wall alterations to accommodate proposed adjacent hospital building revision (included but not limited to retaining wall running along the exterior perimeter of RCC, waterproofing, etc)

    Applied Jan 29, 2025 · issued Nov 21, 2025 · Permit 25 109866 STS

    Permit issued
  • Plumbing

    Plumbing - Reactivation Care Centre exterior wall alterations to accommodate proposed adjacent hospital building revision (included but not limited to retaining wall running along the exterior perimeter of RCC, waterproofing, etc)

    Applied Jan 29, 2025 · issued Nov 21, 2025 · Permit 25 109866 PLB

    Inspections under way
  • Addition or alteration · Multiple projects

    Reactivation Care Centre exterior wall alterations to accommodate proposed adjacent hospital building revision (included but not limited to retaining wall running along the exterior perimeter of RCC, waterproofing, etc). And a new green roof (VN).

    Applied Jan 28, 2025 · issued Nov 21, 2025 · Permit 25 109866 BLD

    Inspections under way
  • Drains and site services

    Drain - Proposal to construct a maintenance shed/garage next to the existing 3 storey long term care building.

    Applied Nov 29, 2024 · issued Jan 8, 2026 · Permit 24 245143 DRN

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct a maintenance shed/garage next to the existing 3 storey long term care building.

    Applied Nov 29, 2024 · issued Jan 8, 2026 · Permit 24 245143 PLB

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct a maintenance shed/garage next to the existing 3 storey long term care building.

    Applied Nov 29, 2024 · issued Jan 8, 2026 · Permit 24 245143 HVA

    Permit issued
  • New building

    Proposal to construct a maintenance shed/garage next to the existing 3 storey long term care building.

    Applied Nov 29, 2024 · Permit 24 245143 BLD

    Examiner's notice sent
  • Drains and site services · Site service

    Site Service Drain - Proposal to add a maintenance shed next to the existing 3 storey long term care buidling.

    Applied Nov 15, 2024 · completed Dec 10, 2024 · Permit 24 237517 STS

    Cancelled
  • Addition or alteration · Other

    Proposal to add a maintenance shed next to the existing 3 storey long term care building.

    Applied Nov 12, 2024 · completed Dec 10, 2024 · Permit 24 237517 BLD

    Cancelled
  • Fire and security upgrade

    FS - Sprinkler Shop Drawing - Proposal to construct interior alterations in an existing care facility - UHN Reactivation Care Centre

    Applied Oct 29, 2024 · issued Aug 22, 2025 · completed Aug 22, 2025 · Permit 24 226092 FSU

    Closed
  • Addition or alteration · Multiple projects

    Proposal to construct interior alterations in an existing care facility - UHN Reactivation Care Centre

    Applied Oct 15, 2024 · issued Dec 12, 2024 · Permit 24 226092 BLD

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct interior alterations in an existing care facility - UHN Reactivation Care Centre

    Applied Oct 15, 2024 · issued Dec 12, 2024 · Permit 24 226092 HVA

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct interior alterations in an existing care facility - UHN Reactivation Care Centre

    Applied Oct 15, 2024 · issued Dec 12, 2024 · Permit 24 226092 PLB

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal for interior demolition in an existing long term care facility - West Park Healthcare Centre

    Applied Sep 16, 2024 · issued Sep 27, 2024 · Permit 24 213269 HVA

    Permit issued
  • Addition or alteration · Interior alterations

    Proposal for interior demolition in an existing long term care facility - West Park Healthcare Centre

    Applied Sep 16, 2024 · issued Sep 26, 2024 · Permit 24 213269 BLD

    Inspections under way
  • Plumbing

    Plumbing - Proposal for interior interior demolition in an existing long term care facility - West Park Healthcare Centre

    Applied Sep 16, 2024 · issued Sep 27, 2024 · Permit 24 213269 PLB

    Permit issued
  • Fire and security upgrade · Electromagnetic locks

    This is an Addendum to our previously issued Maglock Permit 22 108461 FSU 00 FS for an additional maglock in the tunnel that connects the LTC to the new hospital.To construct a new facility/healthcare centre for West Park Healthcare Centre. This permit is specifically for maglocks. 22 108461 FSU 00 FS permit drawing set attached for reference

    Applied Aug 29, 2024 · issued Oct 7, 2024 · Permit 24 205843 FSU

    Permit issued
  • Addition or alteration · Other

    Tunnel Closures for the long term care on either end where the Ruddy and Gage buildings meet the LTC facility.

    Applied Apr 6, 2023 · issued May 17, 2023 · Permit 23 131621 BLD

    Permit issued
  • Demolition

    Demolish Accessory Building of West Park Healthcare Centre in order to construct the North Parking Lot to the new hospital facility (related building permit: 18 245526 BLD 01 NB)

    Applied Mar 16, 2023 · issued Jun 7, 2024 · completed Jul 8, 2025 · Permit 23 123979 DEM

    Closed
  • Designated structure · Sign building permit related

    Application for a permit to erect and display nineteen WALL signs, three of which are illuminated.*****WESTPARK HEALTHCARE CENTRE*****

    Applied Oct 31, 2022 · issued Nov 15, 2022 · completed Oct 27, 2023 · Permit 22 223948 DST

    Closed
  • Designated structure · Sign building permit related

    Application for a permit to erect and display four OVERHANGING STRUCTURE signs, two of which are illuminated and two non-illuminated WINDOW signs.*****WESTPARK HEALTHCARE CENTRE*****

    Applied Oct 31, 2022 · issued Nov 15, 2022 · completed Mar 25, 2025 · Permit 22 224023 DST

    Closed
  • Designated structure · Sign building permit related

    Application for a permit to erect and display 14 ground signs for Westpark Healthcare CentreEXT-5A-3, EXT-5A-4, EXT-5A-9, EXT-6B, EXT-6D, EXT-6E, EXT-7A, EXT-7B, EXT-7C, EXT-5A-5, EXT-5A-6, EXT-6C, EXT-7D, and EXT-15-C.Note: The remaining signs will be reviewed and inspected under Permit 25 194969 ¿ 170 Emmett Ave.

    Applied Oct 28, 2022 · issued Nov 15, 2022 · completed Oct 28, 2025 · Permit 22 223021 DST

    Closed
  • Designated structure · Sign building permit related

    Application for a permit to erect and display twenty-one wall signs, three overhanging structure signs (two of which are illuminated), two window signs, sixty-nine ground signs, only one of which is illuminated. Already approved by ZMP # 21-178913.*****WESTPARK HEALTHCARE CENTRE*****

    Applied Oct 3, 2022 · completed Oct 28, 2022 · Permit 22 212594 DST

    Cancelled
  • Fire and security upgrade · Electromagnetic locks

    Proposal to install 417 maglocks in a proposed hospital - West Park Healthcare CentreSee related building permit 19 232674 BLD.

    Applied Jan 28, 2022 · issued Aug 16, 2022 · completed Oct 27, 2023 · Permit 22 108461 FSU

    Closed
  • Alternative solution

    REVIEW WITH MST GIVEN CLOSE SPACE SPRINKLER DECISIONIn lieu of window sprinklers constructed to ulc/ord c263.1 for sprinkler protectedglazing, it is proposed to install water curtain sprinkler system to protect the curvedglass assembly in the 45 minute rated fire separation that separates the gym on levels 2to 6 from the corridor used by the public.Please refer to report "vft17156 wphc water curtain alt soln 10may2021" for details.

    Applied May 27, 2021 · completed Jun 17, 2021 · Permit 21 161604 ALT

    Cancelled
  • Conditional permit · Partial permit - structural framing

    Conditional Permit - Part Permit - Proposal to construct a new 6 storey facility/ healthcare centre with mechanical penthouse and 3 levels of underground for West Park Healthcare Centre.

    Applied Nov 26, 2020 · issued Dec 24, 2020 · completed Nov 25, 2021 · Permit 19 232674 STR

    Closed
  • Alternative solution

    it is proposed to provide stainless steel piping for potable water services in lieu of copper piping as Alternative solution: required by obc 7.2.7.1.(1). please refer to vortex fire report "vft17156r04 wphc stainless steel piping alt solution 07may2020".

    Applied May 13, 2020 · completed Dec 15, 2020 · Permit 20 144856 ALT

    Approved
  • Conditional permit · Partial permit - foundation

    Conditional Permit - Part Permit - Proposal to construct a new 6 storey facility/ healthcare centre with mechanical penthouse and 3 levels of underground for West Park Healthcare Centre.

    Applied Apr 16, 2020 · issued May 12, 2020 · completed Dec 24, 2020 · Permit 19 232674 FND

    Closed
  • Conditional permit · Partial permit - shoring

    Conditional Permit - Part Permit - Proposal to construct a new 6 storey facility/ healthcare centre with mechanical penthouse and 3 levels of underground for West Park Healthcare Centre.

    Applied Jan 17, 2020 · issued Feb 27, 2020 · completed Dec 24, 2020 · Permit 19 232674 SHO

    Closed
  • Drains and site services · Site service

    Site services permit related to proposal to construct a new facility/healthcare centre for West Park Healthcare Centre.

    Applied Oct 25, 2019 · Permit 19 240976 STS

    Under review
  • New building

    Rev 01: Revised foundation support changesProposal to construct a one storey maintenance building to West Park Hospital site.

    Applied Jul 17, 2019 · issued Aug 26, 2019 · completed Sep 13, 2019 · Permit 18 245526 BLD (revision 01)

    Closed
  • Heating and ventilation

    Rev 01 : Revision to canopy size, mechanical changes, light layout changes.HVAC - Proposal to construct a temporary hospital entrance and awning

    Applied Jul 16, 2019 · issued May 5, 2020 · Permit 19 133704 HVA (revision 01)

    Revision issued
  • Addition or alteration · Multiple projects

    Rev 01 : Revision to canopy size, mechanical changes, light layout changes.Proposal to construct a temporary hospital entrance and awning

    Applied Jul 16, 2019 · issued May 12, 2020 · Permit 19 133704 BLD (revision 01)

    Revision issued
  • Addition or alteration · Other

    Proposal to construct tunnel box for future build.

    Applied Jun 25, 2019 · issued Oct 24, 2019 · Permit 19 178259 BLD

    Inspections under way
  • Addition or alteration · Other

    Proposal to demolish the front entrance canopy of the hospital.

    Applied Apr 18, 2019 · issued Jun 14, 2019 · completed Jul 10, 2025 · Permit 19 142457 BLD

    Closed
  • Heating and ventilation

    HVAC - Proposal to construct a temporary hospital entrance and awning

    Applied Apr 1, 2019 · issued Jul 2, 2019 · Permit 19 133704 HVA

    Inspections under way
  • Addition or alteration · Multiple projects

    Proposal to construct a temporary hospital entrance and awning

    Applied Apr 1, 2019 · issued Jul 2, 2019 · Permit 19 133704 BLD

    Inspections under way
  • Drains and site services · Site service

    REV01: Revision to issued permit 18-251559 STS as per bubbled area.Site servicing permit to modify existing site services in preparation for the construction of a new hospital.

    Applied Feb 4, 2019 · issued Jul 23, 2019 · Permit 18 251559 STS (revision 01)

    Revision issued
  • Addition or alteration · Interior alterations

    Proposal to make interior alterations of a storage room in Long Term Care building which include alterations to a sprinkler system

    Applied Jan 9, 2019 · issued Apr 24, 2019 · Permit 19 102776 BLD

    Permit issued
  • Heating and ventilation

    HVAC - Proposal to make interior alterations of a storage room in Long Term Care building which include alterations to a sprinkler system

    Applied Jan 9, 2019 · Permit 19 102776 HVA

    Response received
  • Demolition

    Proposal to demolish 1 storey maintenance shed 'Building C'.

    Applied Dec 3, 2018 · issued May 7, 2019 · completed Jul 8, 2025 · Permit 18 263608 DEM

    Closed
  • Demolition

    Proposal to demolish 1 storey maintenance shed 'Building B'.

    Applied Dec 3, 2018 · issued May 7, 2019 · completed Jul 8, 2025 · Permit 18 263543 DEM

    Closed
  • Demolition

    Proposal to demolish 1 storey maintenance shed 'Building A'.

    Applied Nov 30, 2018 · issued May 7, 2019 · completed Jul 8, 2025 · Permit 18 263199 DEM

    Closed
  • Drains and site services · Site service

    Site servicing permit to modify existing site services in preparation for the construction of a new hospital.

    Applied Nov 2, 2018 · issued Dec 27, 2018 · Permit 18 251559 STS

    Inspections under way
  • New building

    Proposal to construct a one storey maintenance building to West Park Hospital site.

    Applied Oct 19, 2018 · issued May 27, 2019 · completed Sep 13, 2019 · Permit 18 245526 BLD

    Closed
  • Temporary structure · Certified tents

    PROPOSAL TO INSTALL 30x70 TENT ON OCTOBER 10, 2018. TAKE DOWN ON OCTOBER 11, 2018. CERTIFIED TENT 15-120131

    Applied Oct 2, 2018 · issued Oct 19, 2018 · completed Feb 21, 2019 · Permit 18 236354 TPS

    Closed
  • Fire and security upgrade · Electromagnetic locks

    install 1 maglock on basement elevator lobby egress door & pull station

    Applied Sep 1, 2016 · issued Sep 28, 2016 · completed Dec 14, 2020 · Permit 16 216635 FSU

    Closed
  • Addition or alteration · Interior alterations

    Interior alterations to Medication Rooms and Gage Pod 'E' to West Park Health Care Centre.

    Applied Apr 17, 2012 · issued Jun 4, 2012 · completed Sep 20, 2021 · Permit 12 155216 BLD

    Closed
  • Plumbing

    Plumbing - Interior alterations to Medication Rooms and Gage Pod 'E' to West Park Health Care Centre.

    Applied Apr 17, 2012 · issued Jun 29, 2012 · completed Nov 16, 2020 · Permit 12 155216 PLB

    Closed
  • Heating and ventilation

    HVAC - Interior alterations to Medication Rooms and Gage Pod 'E' to West Park Health Care Centre.

    Applied Apr 17, 2012 · issued Jun 29, 2012 · completed Jun 4, 2021 · Permit 12 155216 HVA

    Closed
  • Addition or alteration · Interior alterations

    interior alterations to restaurant/cafeteria main floor- West Park Hospital

    Applied Nov 21, 2011 · issued Dec 7, 2011 · completed Sep 20, 2021 · Permit 11 313014 BLD

    Closed
  • Fire and security upgrade · Fire alarm

    Fire alarm system upgrade on 4 levels (basement, ground, second and third floor).

    Applied Apr 12, 2011 · issued May 12, 2011 · Permit 11 172434 FSU

    Inspections under way
  • Plumbing

    Plumbing - interior renovations to existing main floor therapy room in Gage Building to provide kitchenett and access from outside department for staff use

    Applied Sep 14, 2010 · issued Oct 28, 2010 · completed Jun 3, 2026 · Permit 10 257720 PLB

    Closed
  • Addition or alteration · Interior alterations

    interior alterations to main floor of Gage BuildingFeb. 12/02, revision to existing pull station (9) to keyed pull stations

    Applied Feb 13, 2002 · issued Feb 26, 2002 · completed Nov 15, 2018 · Permit 01 127793 BLD (revision 01)

    Closed

Committee of Adjustment

This address's applications to the City's Committee of Adjustment since 2017, and any still open. A minor variance asks for a small exception to the zoning by-law, such as a little more height or a smaller setback; a consent divides a lot or grants an easement.

  • Minor variance · Other

    To alter the development standards as outlined in By-law 1396-2024 to maintain the as-built maintenance garage.

    Decision: Approved (hearing Apr 23, 2026)

    Filed Mar 18, 2026 · File A0104/26EYK

    Closed

What’s planned nearby

Development sites within 500 m

Neighbours’ Committee of Adjustment files within 250 m

  • 333 Sidney Belsey Cres · Minor variance

    To maintain the existing apartment building with retail (convenience store) at grade.

    180 m away · filed May 15, 2019 · Approved

Everything planned in York South-Weston

From the City of Toronto’s open data: building permits (active, and cleared since 2017), Committee of Adjustment applications and address points, this record updated Sep 29, 2026, and the development sites from its Development Applications data. Contains information licensed under the Open Government Licence – Toronto. Construction cost estimates and contractors’ names are left out on purpose, and nothing here names an owner.