Toronto address · Ward 4, Parkdale-High Park
133 Roncesvalles Ave
The City of Toronto has 9 building permits since 2017 (9 still open) and 1 Committee of Adjustment file on record for this address.
Building permits
Every permit the City lists for this address since 2017, and any still open from before, newest first.
- Revision issued
Heating and ventilation
REV 01: revise the existing open building, plumbing, and HVAC permit at the property. Our building inspector requested updated drawings to reflect structural changes to the foundation and ground floor that were necessitated due to access constraints and existing fire damage uncovered during demolition. The original scope of work remains unchanged and is as follows: "To alter the existing three-storey mixed-use building (containing ground floor commercial space and two residential dwelling units on the second and third levels) by constructing a rear three-storey addition with a mezzanine level…
Applied Mar 19, 2026 · issued Apr 24, 2026 · Permit 24 246879 HVA (revision 01)
- Revision issued
Plumbing
REV 01: revise the existing open building, plumbing, and HVAC permit at the property. Our building inspector requested updated drawings to reflect structural changes to the foundation and ground floor that were necessitated due to access constraints and existing fire damage uncovered during demolition. The original scope of work remains unchanged and is as follows: "To alter the existing three-storey mixed-use building (containing ground floor commercial space and two residential dwelling units on the second and third levels) by constructing a rear three-storey addition with a mezzanine level…
Applied Mar 19, 2026 · issued Apr 22, 2026 · Permit 24 246879 PLB (revision 01)
- Revision issued
Addition or alteration · Multiple projects
REV 01: revise the existing open building, plumbing, and HVAC permit at the property. Our building inspector requested updated drawings to reflect structural changes to the foundation and ground floor that were necessitated due to access constraints and existing fire damage uncovered during demolition. The original scope of work remains unchanged and is as follows: "To alter the existing three-storey mixed-use building (containing ground floor commercial space and two residential dwelling units on the second and third levels) by constructing a rear three-storey addition with a mezzanine level…
Applied Mar 19, 2026 · issued May 12, 2026 · Permit 24 246879 BLD (revision 02)
- Inspections under way
Drains and site services
Drain - Proposal to alter the existing three-storey mixed-use building (containing ground floor commercial space and two residential dwelling units on the second and third levels) by constructing a rear three-storey addition with a mezzanine level above the third storey and a rear (east) ground floor pedestrian access. This altered building will maintain commercial space on the ground floor and will provide a total of five residential dwelling units on the second and third levels.
Applied Mar 19, 2026 · issued Apr 14, 2026 · Permit 24 246879 DRN
- Revision issued
Addition or alteration · Multiple projects
Revision 01 - an amendment for the open 24_246879_BLD_00_BA permit at 133 Roncesvalles Avenue. During demolition, it was discovered that an existing window opening on the ground floor was framed in and closed, and we're seeking to restore it to its original condition. All else in the original permit is unchangedProposal to alter the existing three-storey mixed-use building (containing ground floor commercial space and two residential dwelling units on the second and third levels) by constructing a rear three-storey addition with a mezzanine level above the third storey and a rear (east) groun…
Applied Dec 24, 2025 · issued Jan 15, 2026 · Permit 24 246879 BLD (revision 01)
- Inspections under way
Plumbing
Plumbing - Proposal to alter the existing three-storey mixed-use building (containing ground floor commercial space and two residential dwelling units on the second and third levels) by constructing a rear three-storey addition with a mezzanine level above the third storey and a rear (east) ground floor pedestrian access. This altered building will maintain commercial space on the ground floor and will provide a total of five residential dwelling units on the second and third levels.
Applied Dec 4, 2024 · issued Jul 8, 2025 · Permit 24 246879 PLB
- Inspections under way
Addition or alteration · Multiple projects
Proposal to alter the existing three-storey mixed-use building (containing ground floor commercial space and two residential dwelling units on the second and third levels) by constructing a rear three-storey addition with a mezzanine level above the third storey and a rear (east) ground floor pedestrian access. This altered building will maintain commercial space on the ground floor and will provide a total of five residential dwelling units on the second and third levels.
Applied Dec 4, 2024 · issued Jul 8, 2025 · 3 homes added · Permit 24 246879 BLD
- Inspections under way
Heating and ventilation
HVAC - Proposal to alter the existing three-storey mixed-use building (containing ground floor commercial space and two residential dwelling units on the second and third levels) by constructing a rear three-storey addition with a mezzanine level above the third storey and a rear (east) ground floor pedestrian access. This altered building will maintain commercial space on the ground floor and will provide a total of five residential dwelling units on the second and third levels.
Applied Dec 4, 2024 · issued Jul 8, 2025 · Permit 24 246879 HVA
- Inspections under way
Heating and ventilation · Special ventilation system
Proposal to install a new kitchen exhaust unit in an existing ground floor restaurant (30 seats).
Applied May 18, 2012 · issued May 23, 2012 · Permit 12 176045 MSA
Committee of Adjustment
This address's applications to the City's Committee of Adjustment since 2017, and any still open. A minor variance asks for a small exception to the zoning by-law, such as a little more height or a smaller setback; a consent divides a lot or grants an easement.
- Closed
Minor variance · Other
To alter the existing three-storey mixed-use building (containing ground floor commercial space and two residential dwelling units on the second and third levels) by constructing a rear three-storey addition with a mezzanine level above the third storey and a rear (east) ground floor pedestrian access. This altered building will maintain commercial space on the ground floor and will provide a total of six residential dwelling units on the second and third levels.
Decision: Approved (hearing Apr 10, 2024)
Filed Jan 25, 2024 · File A0104/24TEY
What’s planned nearby
Development sites within 500 m
No rezoning, site plan, subdivision or condominium file open within 500 m, and no pre-construction project on the site.
Neighbours’ Committee of Adjustment files within 250 m
165 Garden Ave · Minor variance
To alter the existing two-and-one-half-storey townhouse dwelling by enclosing the front third storey balcony into habitable space. Also, to construct a rear second storey addition (above the existing one-storey portion of the dwelling), and a rear third storey rooftop balcony extension.
110 m away · filed May 20, 2026 · Approved
148 Galley Ave · Minor variance
To construct a new one-storey detached ancillary building (to contain a two-car garage), in the rear yard of the existing two-and-one-half-storey detached dwelling, abutting the laneway. The existing rear one-storey detached garage will be demolished.
70 m away · filed Sep 25, 2025 · Application withdrawn
158 Garden Ave · Minor variance
To alter the existing two-storey semi-detached dwelling by constructing a rear two-storey addition, and a rear ground floor deck with stairs. Also, to construct a new one-storey ancillary building (one-car garage) in the rear yard, abutting the laneway. The existing rear deck with stairs, and the existing one-storey ancillary building (garage) will be demolished.
140 m away · filed Sep 11, 2025 · Approved
207 Pearson Ave · Minor variance
To construct a new two-storey ancillary building (containing one parking space, one laneway suite, and a green roof) in the rear yard, abutting the laneway. There will be a total of four residential dwelling units on this lot (three dwelling units within the main house and one dwelling unit within the ancillary building).
180 m away · filed Nov 21, 2024 · Withdrawn
175 Galley Ave · Minor variance
To alter the existing two-storey semi-detached dwelling by constructing a front one-storey addition with a covered porch, a rear basement walkout, a rear two-storey addition with a ground floor deck and stairs, and a rear second storey balcony.
140 m away · filed Nov 1, 2024 · Approved
175 Pearson Ave · Minor variance
To alter the existing two-and-one-half-storey detached dwelling by constructing a rear one-storey addition (containing front and rear canopies, a rear integral garage and a below-grade basement and tunnel connecting to the main house) in the rear yard, abutting the laneway. The existing one-storey ancillary building (detached garage) will be demolished.
180 m away · filed Jul 9, 2024 · Refused
127 Garden Ave · Minor variance
To alter the existing two-storey townhouse dwelling by constructing a rear one-storey addition. A portion of the existing rear ground floor deck will be demolished.
180 m away · filed Jun 30, 2024 · Approved
122 Marion St · Minor variance
To convert the existing two-storey, two-unit detached dwelling with a secondary suite in the basement, into a single-family dwelling, by constructing a rear and partial side two-storey addition with a rear ground floor deck, and a second storey balcony. The existing garage in the rear yard will be maintained and unaltered.
240 m away · filed Jun 29, 2024 · Approved
From the City of Toronto’s open data: building permits (active, and cleared since 2017), Committee of Adjustment applications and address points, this record updated Sep 29, 2026, and the development sites from its Development Applications data. Contains information licensed under the Open Government Licence – Toronto. Construction cost estimates and contractors’ names are left out on purpose, and nothing here names an owner.