The City of Toronto has 17 building permits since 2017 (3 still open) and 1 Committee of Adjustment file on record for this address.

Building permits

Every permit the City lists for this address since 2017, and any still open from before, newest first.

  • Alternative solution

    The sixth floor mechanical floor plans/Drawing M21 were issued for permit depicting floor drains below the exterior pool area within the built-up/void space. The Ontario Building Code 7.4.3.2. (1) "Indirect connections or any trap that may overflow shall not be located in a crawl space or any other unfrequented area". Our office believes it is good engineering practice to add the floor drains to this space considering it is possible that the external elements (rains or snow), as well as, pool water can find its way into the space. In the situation that water does find its way into the space t…

    Applied Sep 20, 2022 · completed Oct 14, 2022 · Permit 22 206198 ALT

    Approved
  • Plumbing

    Revision 02: to the installation of a trap seal guards in random locations. Drawings will be provided to field inspector.Revised Proposal Sep 15, 2020- Proposal to construct a 56-storey residential condominium building with 5 levels of underground parking (inclusive of 1 ramp level to grade) (12 additional dwelling units and two additional storeys) as approved by the Committee of Adjustment - A0598/19EY

    Applied Oct 21, 2021 · issued Oct 21, 2021 · completed Nov 17, 2022 · Permit 17 157681 PLB (revision 02)

    Closed
  • Heating and ventilation

    Revised Proposal Sep 15, 2020- Proposal to construct a 56-storey residential condominium building with 5 levels of underground parking (inclusive of 1 ramp level to grade) (12 additional dwelling units and two additional storeys) as approved by the Committee of Adjustment - A0598/19EY

    Applied Sep 1, 2020 · issued Nov 20, 2020 · completed Oct 12, 2022 · Permit 17 157681 HVA (revision 01)

    Closed
  • Plumbing

    Revised Proposal Sep 15, 2020- Proposal to construct a 56-storey residential condominium building with 5 levels of underground parking (inclusive of 1 ramp level to grade) (12 additional dwelling units and two additional storeys) as approved by the Committee of Adjustment - A0598/19EY

    Applied Sep 1, 2020 · issued Dec 9, 2020 · completed Nov 17, 2022 · Permit 17 157681 PLB (revision 01)

    Closed
  • Alternative solution

    The Alternative Solution is required because the outdoor public pool on the 6th floor is not provided with a 1800mm pool deck on one (1) side (long side) of the pool.

    Applied Dec 10, 2019 · completed Jan 27, 2020 · Permit 19 259286 ALT

    Approved
  • Partial permit · Partial permit - structural framing

    Part Permit - Proposal to construct a 54 storey residential building with five levels of underground parking (inclusive of 1 ramp level to grade).

    Applied Oct 2, 2018 · completed Apr 9, 2020 · Permit 17 157681 STR

    Superseded
  • Alternative solution

    Alternative Solution proposal reviews the requirements of locating the standpipe riser within the exit stair shaft and deleting the fire hose cabinets.

    Applied Jul 6, 2018 · completed Aug 21, 2018 · Permit 18 189658 ALT

    Approved
  • Conditional permit · Partial permit - foundation

    Conditional Permit - Part Permit - Proposal to construct a 54 storey residential building with six levels of underground parking (inclusive of 1 ramp level to grade).

    Applied Mar 13, 2018 · issued Aug 7, 2018 · completed Oct 31, 2018 · Permit 17 157681 FND

    Closed
  • Conditional permit · Partial permit - shoring

    Conditional Permit - Part Permit - Proposal to construct a 54 storey residential building with six levels of underground parking (inclusive of 1 ramp level to grade).

    Applied Feb 20, 2018 · issued Mar 28, 2018 · completed Aug 7, 2018 · Permit 17 157681 SHO

    Cancelled
  • Drains and site services

    Conditional Permit - Part Permit - Proposal to construct a 54 storey residential building with six levels of underground parking (inclusive of 1 ramp level to grade).

    Applied Jan 9, 2018 · issued Aug 8, 2018 · completed Nov 17, 2022 · Permit 17 157681 DRN

    Closed
  • Heating and ventilation

    HVAC - Proposal to construct a 54 storey residential building with five levels of underground parking (inclusive of 1 ramp level to grade).

    Applied May 10, 2017 · issued Nov 28, 2018 · completed Oct 12, 2022 · Permit 17 157681 HVA

    Closed
  • New building

    Revised Proposal Sep 15, 2020- Proposal to construct a 56-storey residential condominium building with 5 levels of underground parking (inclusive of 1 ramp level to grade) (12 additional dwelling units and two additional storeys) as approved by the Committee of Adjustment - A0598/19EYProposal to construct a 54 storey residential building plus 2 storey of mechanical penthouses with five levels of underground parking (inclusive of 1 ramp level to grade)

    Applied May 10, 2017 · issued Jul 5, 2021 · completed Mar 29, 2023 · 504 homes added · Permit 17 157681 BLD

    Closed
Show 5 more permits
  • Drains and site services · Inside and outside drains

    Revised Proposal Sep 15, 2020- Proposal to construct a 56-storey residential condominium building with 5 levels of underground parking (inclusive of 1 ramp level to grade) (12 additional dwelling unitsand two stories) as amended by COA - A0598/19EY.Drain - Site Services- Proposal to install outside services to support the construction of a 54 storey residential building with five levels of underground parking (inclusive of 1 ramp level to grade)

    Applied May 10, 2017 · issued Jul 5, 2021 · completed Nov 17, 2022 · Permit 17 157681 STS

    Closed
  • Plumbing

    Part Permit - Proposal to construct a 54 storey residential building with five levels of underground parking (inclusive of 1 ramp level to grade).

    Applied May 10, 2017 · issued Nov 28, 2018 · completed Nov 17, 2022 · Permit 17 157681 PLB

    Closed
  • Temporary structure · Sales pavilions

    Proposed construction of a (1) storey temporary sales pavilion for the site of a future multipal residential unit condominium buildings.

    Applied Nov 17, 2010 · issued Nov 3, 2017 · completed Mar 7, 2019 · Permit 10 298084 TPS

    Closed
  • Plumbing

    Plumbing - Proposed construction of a (1) storey temporary sales pavilion for site of future multipal residential unit condominium buildings.

    Applied Nov 17, 2010 · issued Nov 3, 2017 · Permit 10 298084 PLB

    Revocation pending
  • Heating and ventilation

    HVAC - Proposed construction of a (1) storey temporary sales pavilion for site of future multipal residential unit condominium buildings.

    Applied Nov 17, 2010 · issued Nov 3, 2017 · completed Sep 30, 2022 · Permit 10 298084 HVA

    Closed

Committee of Adjustment

This address's applications to the City's Committee of Adjustment since 2017, and any still open. A minor variance asks for a small exception to the zoning by-law, such as a little more height or a smaller setback; a consent divides a lot or grants an easement.

  • Consent · Create new Easement/ROW

    To obtain consent to create a reciprocal easement/right-of-way for the purpose of construction and maintenance.

    Decision: Approved (hearing Oct 11, 2018)

    Filed Jun 1, 2018 · File B0052/18EYK

    Closed

What’s planned nearby

Development sites within 500 m

Neighbours’ Committee of Adjustment files within 250 m

  • 2150 Lake Shore Blvd W · Minor variance

    To construct a temporary sales office.

    100 m away · filed Apr 26, 2024 · Approved

  • 2150 Lake Shore Blvd W · Minor variance

    To construct event specific temporary tents for the purposes of hosting shows (Entertainment Place of Assembly).

    100 m away · filed Apr 2, 2024 · Approved

  • 2150 Lake Shore Blvd W · Minor variance

    To modify the approved phasing line from Phase 3 into Phase 1 to accommodate the proposed development.

    100 m away · filed Sep 12, 2023 · Approved

  • 2150 Lake Shore Blvd W · Minor variance

    To construct event specific temporary tents for the purposes of hosting shows (Entertainment Place of Assembly).

    100 m away · filed Feb 7, 2023 · Approved

  • 2161 Lake Shore Blvd W · Minor variance

    To permit a parking deficiency to accommodate new residential, mixed-use and commercial buildings.

    40 m away · filed Apr 20, 2021 · Approved

  • 2161 Lake Shore Blvd W · Minor variance

    To modify the development standards from site specific By-law 572-2016.

    40 m away · filed Nov 20, 2019 · Approved

  • 2183 Lake Shore Blvd W · Minor variance

    To permit a temporary sales office.

    140 m away · filed Mar 27, 2019 · Approved

  • 2175 Lake Shore Blvd W · Minor variance

    To legalize and maintain fourteen undersized as-built parking spaces.

    70 m away · filed Mar 21, 2018 · Approved

Everything planned in Etobicoke-Lakeshore

From the City of Toronto’s open data: building permits (active, and cleared since 2017), Committee of Adjustment applications and address points, this record updated Sep 29, 2026, and the development sites from its Development Applications data. Contains information licensed under the Open Government Licence – Toronto. Construction cost estimates and contractors’ names are left out on purpose, and nothing here names an owner.