Sample data. These listings are fictional examples used to demonstrate the site. No MLS or board data is displayed.

Shaun Lovell, Real Estate SalespersonRight At Home Realty, Brokerage289-813-3318

Toronto address · Ward 3, Etobicoke-Lakeshore

225 Birmingham St

The City of Toronto has 70 building permits since 2017 (43 still open) on record for this address.

Building permits

Every permit the City lists for this address since 2017, and any still open from before, newest first.

  • Addition or alteration · Interior alterations

    TENANT FITOUT OF EXISTING EMPTY UNIT FOR A PROPOSED PHARMACY AND OFFICE CLINIC- base building permit # 20 183812 BLD 00 NB.

    Applied Aug 6, 2026 · Permit 26 215283 BLD

    Response received
  • Heating and ventilation

    Hvac - tenant fitout of existing empty unit for a proposed pharmacy and office clinic

    Applied Aug 6, 2026 · Permit 26 215283 HVA

    Issuance pending
  • Plumbing

    Plumbing - TENANT FITOUT OF EXISTING EMPTY UNIT FOR A PROPOSED PHARMACY AND OFFICE CLINIC

    Applied Aug 6, 2026 · Permit 26 215283 PLB

    Issuance pending
  • Heating and ventilation

    HVAC - Proposed interior alteration to fit out an office

    Applied Oct 2, 2025 · issued Nov 5, 2025 · Permit 25 234126 HVA

    Inspections under way
  • Plumbing

    Plumbing - Proposed interior alteration to fit out an office

    Applied Oct 2, 2025 · issued Nov 5, 2025 · completed Jul 16, 2026 · Permit 25 234126 PLB

    Closed
  • Addition or alteration · Interior alterations

    Proposed interior alteration to fit out an office

    Applied Oct 2, 2025 · issued Nov 5, 2025 · Permit 25 234126 BLD

    Inspections under way
  • Plumbing

    Revision 01: Proposal to revise layout.Plumbing - Proposal for interior alterations - fit-out for dental office.

    Applied Feb 24, 2025 · issued Mar 13, 2025 · completed Sep 8, 2025 · Permit 24 202974 PLB (revision 01)

    Closed
  • Addition or alteration · Interior alterations

    Revision 01: Proposal to revise layout.Proposal for interior alterations - fit-out for dental office.

    Applied Feb 24, 2025 · issued Mar 19, 2025 · completed Aug 20, 2025 · Permit 24 202974 BLD (revision 01)

    Closed
  • Heating and ventilation

    Revision 01: Proposal to revise layout.HVAC - Proposal for interior alterations - fit-out for dental office.

    Applied Feb 24, 2025 · issued Mar 13, 2025 · completed Aug 13, 2025 · Permit 24 202974 HVA (revision 01)

    Closed
  • Designated structure · Sign building permit related

    3 wall signs**laketown dentistry**

    Applied Oct 2, 2024 · issued Oct 4, 2024 · completed Aug 6, 2025 · Permit 24 221131 DST

    Closed
  • Designated structure · Sign building permit related

    3 wall signs**laketown dentistry**

    Applied Sep 5, 2024 · completed Sep 10, 2024 · Permit 24 208487 DST

    Cancelled
  • Addition or alteration · Interior alterations

    Proposal for interior alterations - fit-out for dental office.

    Applied Aug 23, 2024 · issued Nov 13, 2024 · completed Aug 20, 2025 · Permit 24 202974 BLD

    Closed
Show 58 more permits
  • Plumbing

    Plumbing - Proposal for interior alterations - fit-out for dental office.

    Applied Aug 23, 2024 · issued Nov 13, 2024 · completed Sep 8, 2025 · Permit 24 202974 PLB

    Closed
  • Heating and ventilation

    HVAC - Proposal for interior alterations - fit-out for dental office.

    Applied Aug 23, 2024 · issued Nov 13, 2024 · completed Aug 13, 2025 · Permit 24 202974 HVA

    Closed
  • Heating and ventilation

    HVAC - Proposal to construct 9 stacked townhouse units in Block 4. See also Alternative Solution folder 21-237624 ALT.

    Applied Apr 5, 2022 · issued May 31, 2022 · Permit 21 221758 HVA

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct 19 stacked townhouse units in Block 5. See also Alternative Solution folder 21-237625 ALT.

    Applied Apr 5, 2022 · issued May 31, 2022 · Permit 21 221831 HVA

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct 19 stacked townhouse units in Block 5. See also Alternative Solution folder 21-237632 ALT.

    Applied Apr 5, 2022 · issued May 31, 2022 · Permit 21 222292 HVA

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct 10 stacked townhouse units in Block 8. See also Alternative Solution folder 21-237633 ALT.

    Applied Apr 5, 2022 · issued May 31, 2022 · Permit 21 222299 HVA

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct 19 stacked townhouse units in Block 6. See also Alternative Solution folder 21-237630 ALT.

    Applied Apr 5, 2022 · issued May 31, 2022 · Permit 21 222037 HVA

    Inspections under way
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 10 stacked townhouse units, block 8.

    Applied Mar 31, 2022 · issued May 31, 2022 · completed Nov 8, 2023 · Permit 21 222299 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 19 stacked townhouse units, block 5.

    Applied Mar 31, 2022 · issued May 31, 2022 · completed Nov 8, 2023 · Permit 21 221831 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 19 stacked townhouse units, block 6.

    Applied Mar 31, 2022 · issued May 31, 2022 · completed Nov 8, 2023 · Permit 21 222037 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 19 stacked townhouse units, block 7.

    Applied Mar 31, 2022 · issued May 31, 2022 · completed Nov 8, 2023 · Permit 21 222292 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 9 stacked townhouse units, block 4.

    Applied Mar 31, 2022 · issued May 31, 2022 · completed Nov 8, 2023 · Permit 21 221758 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 20 stacked townhouse units in Block 1 atop a one level common underground (parking garage).

    Applied Feb 2, 2022 · issued Mar 21, 2022 · completed Jun 25, 2025 · Permit 20 186233 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 24 stacked townhouse units, in Block 10 atop a one level common underground (parking garage).

    Applied Feb 2, 2022 · issued Mar 21, 2022 · completed Nov 8, 2023 · Permit 20 186395 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct commercial building (CRU Block - Block 12) atop a one level common underground (parking garage).

    Applied Feb 2, 2022 · issued Mar 21, 2022 · completed Jun 24, 2025 · Permit 20 183812 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 24 stacked townhouse units in Block 11 atop a one storey common below grade parking facility.

    Applied Feb 2, 2022 · issued Mar 21, 2022 · completed Nov 8, 2023 · Permit 20 186411 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 28 stacked townhouse units in Block 3 atop a one level common underground (parking garage).

    Applied Feb 2, 2022 · issued Mar 21, 2022 · completed Nov 27, 2023 · Permit 20 186307 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 12 stacked townhouse units in Block 9 atop a one level common underground (parking garage).

    Applied Feb 2, 2022 · issued Mar 21, 2022 · completed Nov 8, 2023 · Permit 20 186374 BLD

    Closed
  • Conditional permit · New building

    Conditional Permit - Proposal to construct 24 stacked townhouse units in Block 2 atop a one level common underground (parking garage).

    Applied Feb 2, 2022 · issued Mar 21, 2022 · completed Jun 25, 2025 · Permit 20 186246 BLD

    Closed
  • Heating and ventilation

    HVAC - Proposal to construct 24 stacked townhouse units in Block 11 atop a one storey common below grade parking facility (see related building permit 20-183634). See also Alternative Solution folder 20-215583 ALT.

    Applied Feb 1, 2022 · issued Mar 21, 2022 · Permit 20 186411 HVA

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct 24 stacked townhouse units, in Block 10 atop a one level common underground (parking garage) building in related building permit 20 183634. See also Alternative Solution folder 20-215583 ALT.

    Applied Feb 1, 2022 · issued Mar 21, 2022 · Permit 20 186395 HVA

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct 12 stacked townhouse units in Block 9 atop a one level common underground (parking garage) building in related building permit 20 183634. See also Alternative Solution folder 20-215578 ALT.

    Applied Feb 1, 2022 · issued Mar 21, 2022 · Permit 20 186374 HVA

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct 24 stacked townhouse units in Block 2 atop a one level common underground (parking garage) building in related building permit 20 183634. See also Alternative Solution folder 20-215490 ALT.

    Applied Feb 1, 2022 · issued Mar 21, 2022 · Permit 20 186246 HVA

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct 28 stacked townhouse units in Block 3 atop a one level common underground (parking garage) building in related building permit 20 183634. See also Alternative Solution folder 20-215512 ALT.

    Applied Feb 1, 2022 · issued Mar 21, 2022 · Permit 20 186307 HVA

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct 20 stacked townhouse units in Block 1 atop a one level common underground (parking garage) building in related building permit 20 183634. See also Alternative Solution folder 20-215469 ALT.

    Applied Dec 20, 2021 · issued Mar 21, 2022 · Permit 20 186233 HVA

    Inspections under way
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair with concealed sprinklers on each…

    Applied Nov 15, 2021 · completed Apr 26, 2022 · Permit 21 237632 ALT

    Approved
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair with concealed sprinklers on each…

    Applied Nov 15, 2021 · completed Apr 26, 2022 · Permit 21 237633 ALT

    Approved
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair on the north side of the building…

    Applied Nov 15, 2021 · completed Apr 26, 2022 · Permit 21 237624 ALT

    Approved
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair with concealed sprinklers on each…

    Applied Nov 15, 2021 · completed Apr 26, 2022 · Permit 21 237625 ALT

    Approved
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair with concealed sprinklers on each…

    Applied Nov 15, 2021 · completed Apr 26, 2022 · Permit 21 237630 ALT

    Approved
  • Plumbing

    Plumbing - Proposal to construct 10 stacked townhouse units, block 8.

    Applied Oct 6, 2021 · issued May 31, 2022 · Permit 21 222299 PLB

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct 19 stacked townhouse units, block 7.

    Applied Oct 6, 2021 · issued May 31, 2022 · Permit 21 222292 PLB

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct 9 stacked townhouse units, block 4.

    Applied Oct 5, 2021 · issued May 31, 2022 · Permit 21 221758 PLB

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct 19 stacked townhouse units, block 5.

    Applied Oct 5, 2021 · issued May 31, 2022 · Permit 21 221831 PLB

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct 19 stacked townhouse units, block 6.

    Applied Oct 5, 2021 · issued May 31, 2022 · Permit 21 222037 PLB

    Inspections under way
  • Conditional permit · Inside and outside drains

    Conditional Permit - Drain - Proposal to install the site service works to serve the development of the lands for 200 townhouse dwelling units in 11 residential construction blocks and 1street front commercial building.

    Applied Mar 17, 2021 · issued Jul 26, 2021 · completed Feb 23, 2024 · Permit 20 183634 STS

    Cancelled
  • Conditional permit · New building

    Conditional Permit -Construct one level common underground (parking garage) building for a mixed use development consisting of 200 townhouse dwelling units in 11 interior residential blocks and 1street front commercial building. The parking facility serves at the foundation of the buildings located in the Phase 1 portion of the development lands inclusive of Block -3 and 9-12.

    Applied Mar 4, 2021 · issued Apr 13, 2021 · completed Nov 8, 2023 · Permit 20 183634 BLD

    Closed
  • Addition or alteration · Shoring

    Revision 01- Please refer to enclosed cover letter.Proposal for Shoring and excavation work to remediate the soil in order to obtain a Record of Site Condition for future development. A total of 148.5 linear meters of shoring is proposed.

    Applied Dec 14, 2020 · issued Mar 24, 2021 · completed Jun 30, 2025 · Permit 17 116258 BLD (revision 01)

    Closed
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair with concealed sprinklers on each…

    Applied Nov 5, 2020 · completed Mar 4, 2022 · Permit 20 215512 ALT

    Approved
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair with concealed sprinklers on each…

    Applied Nov 5, 2020 · completed Mar 4, 2022 · Permit 20 215490 ALT

    Approved
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair with concealed sprinklers on each…

    Applied Nov 5, 2020 · completed Mar 4, 2022 · Permit 20 215583 ALT

    Approved
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair with concealed sprinklers on each…

    Applied Nov 5, 2020 · completed Mar 4, 2022 · Permit 20 215469 ALT

    Approved
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair with concealed sprinklers on each…

    Applied Nov 5, 2020 · completed Mar 4, 2022 · Permit 20 215578 ALT

    Approved
  • Alternative solution

    In line with OBC 9.9.4.4.(1). where an unenclosed stair or ramp provides only means of egress from a suite and is exposed to fire from openings in the exterior walls of another fire compartment within 3 m horizontally and 10 m above or 5 m below the exterior exit stair, such openings are required to be protected with wired glass in fixed frame or glass block conforming to OBC 9.10.13.5. and 9.10.13.7. respectively. It is proposed to protect the windows in the townhouse units which are within 3 m horizontally and 10 m above or 5 m below the exterior exit stair with concealed sprinklers on each…

    Applied Nov 5, 2020 · completed Mar 4, 2022 · Permit 20 215584 ALT

    Approved
  • Plumbing

    Plumbing - Proposal to construct 12 stacked townhouse units in Block 9 atop a one level common underground (parking garage) building in related building permit 20 183634. See also Alternative Solution folder 20-215578 ALT.

    Applied Aug 27, 2020 · issued Mar 21, 2022 · Permit 20 186374 PLB

    Inspections under way
  • Plumbing

    Plumbing -Proposal to construct 24 stacked townhouse units in Block 2 atop a one level common underground (parking garage) building in related building permit 20 183634. See also Alternative Solution folder 20-215490 ALT.

    Applied Aug 27, 2020 · issued Mar 21, 2022 · Permit 20 186246 PLB

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct 20 stacked townhouse units in Block 1 atop a one level common underground (parking garage) building in related building permit 20 183634. See also Alternative Solution folder 20-215469 ALT.

    Applied Aug 27, 2020 · issued Mar 21, 2022 · Permit 20 186233 PLB

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct 28 stacked townhouse units in Block 3 atop a one level common underground (parking garage) building in related building permit 20 183634. See also Alternative Solution folder 20-215512 ALT.

    Applied Aug 27, 2020 · issued Mar 21, 2022 · Permit 20 186307 PLB

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct 24 stacked townhouse units in Block 11 atop a one storey common below grade parking facility (see related building permit 20-183634). See also Alternative Solution folder 20-215583 ALT.

    Applied Aug 27, 2020 · issued Mar 21, 2022 · Permit 20 186411 PLB

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct 24 stacked townhouse units, in Block 10 atop a one level common underground (parking garage) building in related building permit 20 183634. See also Alternative Solution folder 20-215583 ALT.

    Applied Aug 27, 2020 · issued Mar 21, 2022 · Permit 20 186395 PLB

    Inspections under way
  • Plumbing

    Plumbing - Proposal to construct one level common underground (parking garage) building serving as the foundation of the development on the lands for a mixed use development consisting of 200 townhouse dwelling units in 11 interior residential blocks and 1street front commercial building.

    Applied Aug 21, 2020 · issued Nov 15, 2021 · Permit 20 183634 PLB

    Inspections under way
  • Heating and ventilation

    HVAC - Proposal to construct one level common underground (parking garage) building serving as the foundation of the development on the lands for a mixed use development consisting of 200 townhouse dwelling units in 11 interior residential blocks and 1street front commercial building.

    Applied Aug 21, 2020 · issued Apr 13, 2021 · Permit 20 183634 HVA

    Inspections under way
  • Drains and site services

    Drain - Proposal to construct one level common underground (parking garage) building serving as the foundation of the development on the lands for a mixed use development consisting of 200 townhouse dwelling units in 11 interior residential blocks and 1street front commercial building.

    Applied Aug 21, 2020 · issued Apr 13, 2021 · Permit 20 183634 DRN

    Inspections under way
  • Heating and ventilation

    Plumbing - Proposal to construct commercial building (CRU Block - Block 12) atop a one level common underground (parking garage) building in related building permit 20 183634.

    Applied Aug 21, 2020 · issued Mar 21, 2022 · Permit 20 183812 HVA

    Permit issued
  • Plumbing

    Plumbing - Proposal to construct commercial building (CRU Block - Block 12) atop a one level common underground (parking garage) building in related building permit 20 183634.

    Applied Aug 21, 2020 · issued Mar 21, 2022 · Permit 20 183812 PLB

    Inspections under way
  • Designated structure · Sign building permit related

    To erect and display one static non-illuminated griound sign.**MENKES LAKE & TOWN TOWNHOMES**

    Applied Aug 28, 2018 · issued Sep 24, 2018 · completed Oct 30, 2018 · Permit 18 216555 DST

    Closed
  • Addition or alteration · Shoring

    Proposal for Shoring and excavation work to remediate the soil in order to obtain a Record of Site Condition for future development. A total of 148.5 linear meters of shoring is proposed.

    Applied Feb 13, 2017 · issued Jul 7, 2017 · completed Jun 30, 2025 · Permit 17 116258 BLD

    Closed
  • Demolition

    Proposal for full demolition of existing two-storey warehouse building.

    Applied Jun 1, 2016 · issued Sep 21, 2016 · completed Jun 6, 2017 · Permit 16 165851 DEM

    Closed

Committee of Adjustment

No applications to the City's Committee of Adjustment for this address since 2017. That's where an owner asks for a minor variance (a small exception to the zoning by-law) or a consent to divide a lot.

What’s planned nearby

Development sites within 500 m

Neighbours’ Committee of Adjustment files within 250 m

  • 39 Fifteenth St · Minor variance

    To construct a new triplex dwelling and a new garden suite in the rear yard.

    190 m away · filed Oct 6, 2023 · Approved

  • 27 Fifteenth St · Minor variance

    To construct a two-storey rear addition and a second storey addition over the existing dwelling. To convert a portion of the existing dwelling into an attached garage.

    210 m away · filed Apr 20, 2022 · Approved

  • 58 Fourteenth St · Minor variance

    To construct a new detached dwelling with an attached garage.

    150 m away · filed Mar 17, 2022 · Approved

  • 27 Fifteenth St · Minor variance

    To construct a one-storey rear addition, a new attached garage and a second storey addition above the existing dwelling.

    210 m away · filed Feb 10, 2022 · Refused

  • 27 Fifteenth St · Minor variance

    To construct a second storey addition and a two-storey rear addition.

    210 m away · filed Oct 9, 2021 · Refused

  • 11 Fourteenth St · Minor variance

    To construct two secondary suites within the existing dwelling, there will be a total of 3 residential units.

    130 m away · filed Jul 26, 2018 · Deferred

  • 7 Fourteenth St · Minor variance

    To construct a two-storey south side addition and a second storey front addition.

    140 m away · filed Dec 20, 2016 · Approved

Everything planned in Etobicoke-Lakeshore

From the City of Toronto’s open data: building permits (active, and cleared since 2017), Committee of Adjustment applications and address points, this record updated Sep 29, 2026, and the development sites from its Development Applications data. Contains information licensed under the Open Government Licence – Toronto. Construction cost estimates and contractors’ names are left out on purpose, and nothing here names an owner.